PRODUCT DETAILS
FireProtect 2 AC is a mains-powered detector designed for residential fire safety. The unique smoke chamber does not require regular cleaning, and sophisticated software minimizes false alarms. The dual-spectrum sensor instantly distinguishes smoke from steam, and two thermistors quickly react to the synthetic materials’ burning. The carbon monoxide sensor alarms before the concentration level becomes threatening. Everything meets the latest fire safety standards. Thought-out design, improved mounting panel with WAGO 221 connectors, and in-app settings make the installation process nice and easy, giving an ultimate experience for PRO.
Patented smoke chamber technology
Encouraged by world standards and best practices, Ajax reaches an entirely new level of technology in residential fire safety with FireProtect 2 AC. A unique smoke chamber that is dustproof and impenetrable for insects, a dual-spectrum optical sensor, and a proprietary HazeFlow 2 software algorithm guarantee the speed and accuracy of fire detection — ultimate safety with no stress about false alarms.
Protects from invisible danger
Carbon monoxide (CO) is colourless, odorless, and otherwise imperceptible without a carbon monoxide detector, so poisoning can occur unnoticed. Even low concentrations can be enough to have a negative health impact, especially on those with chronic illnesses, pregnant, the elderly, and young children. High-level exposure can cause permanent damage or even death in a very short period of time. FireProtect 2 AC warns about a dangerous CO concentration at the level of 50 ppm before even the first signs of poisoning occur. A built-in chemical sensor is responsive to low concentrations and can accurately detect the CO level straight up to 10 years.
Impenetrable for dust and insects
The smoke chamber is designed with zero possibility of contamination that can affect detection. A unique circulation mechanism provides the optical sensor with an unobstructed field to quickly identify products of combustion in the air.
Ignores сooking fumes and water steam
The smoke chamber is hardwired with a dual-spectrum optical sensor that has blue and infrared LEDs with different wavelengths. It uses the most reliable real-time detection method, directly measuring the microparticle concentration in the air. This technology allows FireProtect 2 AC to determine the size of the volatile particles inside the chamber and respond only to smoke, ignoring vapour and water steam.
Enhanced wireless interconnection
All FireProtect 2 AC detectors can synchronously notify about the fire alarm in two ways: primary and fallback . In case of danger, the initiating detector sends a fire alarm to the hub. The hub initiates the primary interconnect: all fire detectors will activate the built-in sirens in 20 seconds — three times faster than the fire standard requires. All information is immediately available in Ajax apps: initiating detector’s location, alarm type, and exact time. If there is no connection with the hub, the initiating detector activates the fallback interconnection bydirectly sending the alarm to other fire detectors. It takes only 1 minute to raise an alarm.
Features:
- Wireless heat & smoke detector
- Dustproof smoke chamber
- SmartBracket with adjustable rotation angle
- Quick and easy to fit
- 85 dB siren
- Dual spectrum optical smoke sensor
- White or black
- Ignores сooking fumes and water steam
- Powered by 110–240 V~ mains and has a sealed battery to serve as a backup
- Different sound and LED indications
- Enhanced wireless interconnection
- Monitoring with PRO Desktop
Communication |
|
Jeweller communication
technology |
Proprietary wireless communication
technology to transmit commands, alarms, and events. Key features: Two-way communication. Advanced anti-sabotage. Block encryption featuring a dynamic key. Instant notifications. Remote configuration in the Ajax apps. |
Frequency bands |
866.0 – 866.5 MHz 868.0 – 868.6 MHz 868.7 – 869.2 MHz 905.0 – 926.5 MHz 915.85 – 926.5 MHz 921.0 – 922.0 MHz |
Maximum effective radiated power
(ERP) |
up to 20 mW |
Radio signal modulation |
GFSK |
Radio communication range |
up to 1,700 m |
Encrypted communication |
All stored and transmitted data are
protected by block encryption featuring a dynamic key. |
Frequency hopping |
Radio communication uses frequency
hopping to prevent interception and jamming. |
Sensitive
elements |
|
Sensitive elements |
smoke sensor heat sensor CO (carbon monoxide) sensor |
Smoke detection |
|
Sensitive element |
double-spectrum optical sensor Detects smoke by the size of particles in the air. |
Protection from false alarms |
Does not react to water
vapor. |
Patented smoke chamber |
Protects the smoke sensor from dust,
dirt, and insects |
Dangerous temperature
detection |
|
Sensitive element |
according to the requirements for Class
A1R heat detectors Requirements of EN 54-5 and BS 5446-2 standards. |
High temperature alarm |
at temperatures above 64°C |
Temperature spike alarm |
when the temperature rises by more than
10°C in 1 minute or less |
Carbon monoxide (CO)
detection |
|
Sensitive element |
chemical CO sensor |
Alarm if accumulated dose of CO is exceeded |
over 50 ppm (0.005%) — in 90 minutes or less over 100 ppm (0.01%) — in 40 minutes or less over 300 ppm (0.03%) — in 3 minutes |
Sensor service life |
10 years |
Additional
features |
|
Built-in siren |
volume 85 dB at a distance of 3
meters Sound notification of alarms. Remains active until the reason for triggering is eliminated or until the user manually disables the notification. |
Interconnected fire detectors
alarms |
via primary interconnection If one of the fire detectors in the system detects a threat, it sends an alarm to the hub. Within 20 seconds, the hub initiates an interconnected alarm and sends data to Ajax apps. via fallback interconnection At the same time with notifying the hub, the initiating detector sends an alarm directly to other detectors. All connected detectors activate the buzzer within a minute. It will work even in the worst-case scenario of losing connection with the hub. |
LED indication |
green is a power indication An LED indicator on the device enclosure lights continuously when powered by an external power source. If the device draws power from the backup battery, the LED indicator lights up once every 56 seconds. This indication complies with the requirements stipulated in EN 14604 and EN 50291 standards. yellow is a malfunction indication An LED indicator on the device enclosure lights up to signal detected malfunctions. This can occur in instances such as battery depletion, smoke chamber contamination, or reaching the end of the service life. red is a fire alarm indication An LED indicator on the device enclosure lights up when the detector registers a fire alarm. |
Button on the front panel of the
detector |
In normal mode, when pressed, it starts
the smoke chamber test. In the event of an alarm or malfunction,
the pressing turns off the detector sound notification. |
External power supply |
110–240 V~, 50/60 Hz The phase and neutral cables from the external power supply should be connected to the WAGO terminals on SmartBracket mounting panel. To remove the detector from SmartBracket, there is no need to disconnect the power cables. |
Recommendations |
|
Recommendations |
The device is designed for indoor
installation only. SmartBracket mounting panel allows adjusting the position of the detector even after installation. |
Sabotage
protection |
|
Tamper alarm |
Notifications on attempts to detach the
detector from the surface or remove it from the mounting
panel. |
Protection against spoofing |
device authentication |
Communication loss detection |
within 15 minutes The time required to detect a communication loss depends on the settings for the number of undelivered data packages (specified in the Jeweller or Jeweller/Fibra settings). |
Power supply |
|
Main |
110–240 V~, 50/60 Hz |
Backup |
1 non-replaceable lithium battery CR-2/3AZ |
Enclosure |
|
Dimensions |
122 x 122 x 54 mm |
Weight |
318 g |
Operating temperature range |
from 0°С to +50°С |
Operating humidity |
up to 80% |
Colours |
Black or white |
Complete set |
FireProtect 2 AC (Heat/Smoke/CO) Jeweller SmartBracket mounting panel WAGO 221 3-conductor terminal — 2 pcs. (pre-installed in SmartBracket) Installation kit Quick start guide |
Videos |
---|
Files |
---|
Ajax FireProtect 2 AC (Heat/Smoke/CO) Datasheet |
Ajax FireProtect 2 AC (Heat/Smoke/CO) User Manual |
Links* |
---|
Ajax website |
Ajax support site |
* External websites provide additional content that supports the content on connectec.uk however the external Web site is subject to change and is beyond the control of Connectec Ltd. Connectec cannot guarantee the accuracy of content on external websites and does not endorse the information or products on any external websites. You will be subject to the external websites own privacy policy when you follow these links.
Get expert answers to questions specific to this product below or for more help visit our Q&A forum
Be the first to ask a question and help others interested in this product
Read customer reviews or submit your review of this product
Your feedback helps us improve our products and services as well as helping other users make informed buying decisions.
There are no reviews for this product.
Why buy from Connectec?
SUPPORT
Our technical support team are experienced installation engineers with years of field experience.
SERVICE
Customer service is our top priority. We always try to ensure we offer a first class service too all our customers.
DELIVERY
We offer FREE mainland UK delivery on orders over £75 and FREE next day delivery on orders over £150*.
PARTNERS
We are approved resellers for direct access to manufacturer warranty and support.
* Qualifying products only, subject to terms. For more information view our delivery information.